Give Us A Call: (800) 872-3684

Novatek Novair 700 / HEPA Filtered Air Purifier­

$995.00
In stock
SKU
AM0115

The Novatek Novair 700 is used in many applications ranging from asbestos removal, restoration projects, airborne pathogens and medical uses.

Novair 700 / HEPA Filtered Air Purifier

Remediation, air scrubbing, restoration, healthcare, and clean rooms are only a few applications for the new Novair 700 portable air filtration unit. Available in a variety of power sources (115v-220v 50/60Hz) and filter configurations.

More power: The Novair 700 is the most powerful impeller driven variable speed adjustment, is capable of delivering 200-700 CFM and dramatically increases filter life.

Versatility: The Novair 700 portable air filtration is at home in applications ranging from asbestos removal, restoration projects, airborne pathogens and medical uses. The tri gasketing and HEPA filter sealing flange, guarantee leak proof operation. The quick release intake door accepts MERV, carbon, and standard dust filters. Integrated nesting allows for the stacking of multiple machines. The built-in GFCI outlet allows you to connect multiple equipment up to 15 amps.

Virtually indestructible: The heavy duty roto molded polyethylene shell, is dent proof, leak proof and virtually indestructible.

Standard filters: 16″ x 16″ x 3″ high capacity HEPA filter is standard. No outrageously priced proprietary filters needed. These economical filters are readily available.

Low power requirements: Drawing only 3 amps, the 700 can be daisy chained up to three units. The built in GFCI outlets allow for safe and effective operation. The Novair’s straight through design makes it ideal for virtually any application.

Utilizes standard “Lay flat” or flex ducting: 10 to 12 inch vacuum ports allows for maximum airflow with little restriction.

 

Specifications

  • Weight: 45 lbs.
  • Dimensions: 22" x 22" x 21" (55cm x 55cm x 52cm)
  • Air Volume: 200- 700 cfm
  • Power Requirements: 115v 3 amp, 50/60 Hz
  • Filtration: HEPA, MERV 8 Box Ring Filter
  • Part No.: F0700 - 115v
More Information
Brand Novatek
Dimensions 22" x 22" x 21"
Air Filtration Tool Type Air Purifier
CFM 200- 700 cfm
Current 3 Amp
Voltage 115V
Frequency 50/60hz
Filtration HEPA, MERV 8 Box Ring Filter

Prior to Use

  1. Wrap and inspect power cord.
  2. Remove any excess dust/dirt from exterior housing and control panel.
  3. Be sure the HEPA Filter and Pre-Filters are installed properly with a positive seal.
  4. Insure the unit is connected to a 115 volt grounded outlet.
  5. Make sure unit is safely positioned as not to impede any entrances or exits of the work area.
  6. If applicable, check exhaust port connections for tight seal.

Operation

  1. A. When utilized in containment, the Novair 700 should be positioned a minimum distance away from the entrance and located towards the center of the containment.
  2. When working with contaminants, insure the HEPA filter is correctly installed and sealed.
  3. Install the pre-filter and pleated filters into unit.
  4. Insert the female end of the power cord, into the grounded 115v outlet.
  5. To begin operation, depress the green circuit breaker switch to the on position. The green light will be lit on the breaker if working properly. This must be in the on position to use GFCI outlet.
  6. Turn the variable speed dial to operate the fan from 200 -700CFM from high to low.
  7. A total of three units can be connected together to create a negative pressure in different parts of the containment area.

Safety

Novatek Negative Air Machines are highly efficient systems designed to reduce air borne particulates. To insure proper operation, the following safety precautions should be strictly adhered to:

  1. Do not leave machine unattended when connected to a power source. Turn OFF electric supply and disconnect from power source when not in use and/or before servicing.
  2. Do not operate with damaged or malfunctioning parts. If the unit is not working as intended, return to an Authorized Repair and Service Center. NOTE: Always replace worn or damaged components with genuine NOVATEK parts. Failure to comply could result in equipment failure and will void warranty. 
  3. Remove any loose clothing and adornments prior to operation.
  4. Keep outer surfaces free of dirt and debris. Be sure all controls clean and functioning properly.
  5. Turn off power prior to any filter inspection and replacement.
  6. Do not operate unit with flammable or combustible liquids or gases present.
  7. Do not operate the machine in wet conditions. Failure to do so could result in electrical shock or death.
  8. Never operate the unit if there is any possibility of contact with the blower wheel.
  9. It is the responsibility of the unit owner to ensure that all equipment is maintained in safe and efficient operating condition.
  10. Stacking of machines is limited to three units. Do not house stacked machines in areas hotter than 100 degrees Fahrenheit. (Failure to comply will void warranty.)